Technical Specifications Table 216: P599 Series Electronic Pressure Transducers Technical Specifications Specification Description Signal Output Types 0.5 to 4.5 VDC Ratiometric 0 to 10 VDC 4 to 20 mA 0 to 5 VDC 1 to 5 VDC Pressure Port Type [Required Assembly Torque] 1/8 in. - 27 NPT, external thread ANSI B1.20.1 [16.26 N•m (12 ft•lb)] 1/4 in. SAE 45° flare, external thread [16.26 N•m (12 ft•lb)] 1/4 in. SAE 45° flare with Schrader ® Valve depressor, internal thread [16.26 N•m(12 ft•lb)] 1/4 in. - 18 NPT, external thread ANSI B1.20.1 [20.33 N•m (15 ft•lb)] 1/2 in. - 20 UNF-2A external, [20.33 N•m (15 ft•lb)] 1/4 in. - 18 NPTF external, [20.33 N•m (15 ft•lb)] M16 X 1.5 Ermeto ® internal thread, ISO 8434-1 [33.89 N•m (25 ft•lb)] Electrical Connector AMP, 174357-2 Hirschmann Form C, 9.5 mm EN 175 301 - 803 Hirschmann Form A, 18 mm EN 175 301 - 803 Packard, Metri-Pack 150 series, P2S Shielded cable; shield not connected to the sensor body M12 X 1P, DS/EN 60947-5-2 Units of Measurement BARS (PSIS) BARA (PSIA) Temperature Range Compensated temperature: -40° to 125°C (-40° to 257°F) Media temperature (pressure side): -40° to 125°C (-40° to 257°F) Operating temperature (ambient air): -40° to 100°C (-40° to 212°F) Storage temperature, -40° to 125°C (-40° to 257°F) Accuracy Total accuracy: +/- 1.5% Best-Fit Straight Line (BFSL): +/- 0.5% Long term stability (1 year): +/- 1.25% Required Output Signal Supply Voltage 0.5 to 4.5 VDC Ratiometric: 4.75 to 5.25 VDC 0 to 10 VDC: 12 to 33 VDC 4 to 20 mA: 9 to 32 VDC 0 to 5 VDC and 1 to 5 VDC: 9 to 33 VDC Maximum Signal Input Current 0.5 to 4.5 VDC Ratiometric: 3 mA 0 to 10 VDC: 5 mA 4 to 20 mA: 24 mA 0 to 5 VDC and 1 to 5 VDC: 5 mA Electrical Protection • Standard response time: 5 mS, +/- 4 mS • Output impedance: greater than 25 ohm • Output load shall be greater than 10K ohm (resistance signal out can support for volt out models) • Reverse wiring protection: (+ and common) (+ and signal out) (common and signal out) • Short-circuit protected: (signal out at maximum span to earth) • Minimum ohms (body to term): 100 M ohm at 500 VDC Physical • Pressure cycles: 10 million full scale • Burst pressure for transducers with Pmax < 52 bar (750 psi): 259 bar (3,750 psi) • Burst pressure for transducers with Pmax > 52 bar (750 psi): 1,034 bar (15,000 psi) • Proof pressure: 3x full-scale (Pmax) for 1 minute • Minimum pressure: 0 bar (0 psia) indefinitely • Proof pressure: 2x full-scale indefinitely • Vibration: 16.4 G random • Mechanical shock: EN 60068-2-27 (25 g, 11 ms, half sine) • Shock/drop: 4 meter 6 times any axis • Piezoresistive sensor filled with silicone oil • All media side materials: 304L stainless steel • Mechanical damping: built-in snubber 188 Refrigeration Products Catalog

Articles in this issue

Archives of this issue

view archives of Wolseley - PENN Controls Products Catalog