Wolseley

PENN Controls Products Catalog

Issue link: https://boomart.uberflip.com/i/1442607

Contents of this Issue

Navigation

Page 308 of 367

Table 330: Reset System 450 Modules and Accessories Ordering Information Product Code Number Product Description PLT344-1R DIN Rail End Clamps (Two clamps) WHA- C450-100C System 450 module connection extension cable, 100 cm (3.3 ft) long Technical specifications Table 331: C450RBN-3C and C450RCN-3C Reset Control Modules with Real-Time Clock and Relay Output Technical Specifications Specification Description Product C450RBN-3C and C450RCN-3C: System 450 Reset Control Module models are sensing controls and operating controls with LCD, four-button touchpad, and SPDT relay output C450RBN-3C: Control Module with one SPDT output relay C450RCN-3C: Control Module with two SPDT output relays Power Consumption C450RBN-3C: 0.9 VA maximum C450RCN-3C: 1.3 VA maximum Supply Power Internal Supply Power: C450YNN-1C Power Supply Module External Supply Power: 24 VAC (20 to 30 VAC) Safety Extra-Low Voltage (SELV) (Europe), Class 2 (North America), 50/60 Hz, 10 VA minimum Note: A System 450 control module or module assembly can use an internal or an external supply power source, but must not be connected to both simultaneously. Ambient Operating Conditions Temperature: -40 to 66°C (-40 to 150°F) Humidity: Up to 95% RH noncondensing; maximum dew point 29°C (85°F) Ambient Shipping and Storage Conditions Temperature: -40 to 80°C (-40 to 176°F) Humidity: Up to 95% RH noncondensing; maximum dew point 29°C (85°F) Input Signal 0 to 5 VDC for humidity sensors 1,035 ohms at 25°C (77°F) for A99 PTC temperature sensors Table 331: C450RBN-3C and C450RCN-3C Reset Control Modules with Real-Time Clock and Relay Output Technical Specifications Specification Description General: 1/2 HP at 120/240 VAC, SPDT Output Relay Contacts Specific: AC Motor Ratings 120 VAC • AC Full-Load Amperes: 9.8 A • AC Locked-Rotor Amperes: 58.8 A 208/240 VAC • AC Full-Load Amperes: 4.9 A • AC Locked-Rotor Amperes: 29.4 A _______________________________________________________ 10 Amperes AC Non-inductive at 24 / 240 VAC Pilot Duty: 125 VA at 24 / 240 VAC Clock Accuracy ±4 minutes per year Clock Backup Power 12 hours (capacitor reserve) Setback Events One occupied and one unoccupied event per day; 7 day schedule Analog Input Accuracy Resolution: 14 bits Control Construction Independently mounted control, surface mounted with Lexan ® 950 enclosure suitable for DIN rail mounting or direct mounting to a hard, even surface. Dimensions (H x W x D) 127 x 61 x 61 mm (5 x 2-3/8 x 2-3/8 in.) Weight C450RBN-3C: 209 g (0.46 lb) C450RCN-3C: 222 g (0.49 lb) Compliance United States: cULus Listed; UL 60730-1, File E27734; FCC Compliant to CFR47, Part 15, Subpart B, Class B Canada: cULus Listed; CAN/CSA-E60730-1, File E27734; Industry Canada (IC) Compliant to Canadian ICES-003, Class B limits Europe: CE Mark – Johnson Controls declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive. Australia and New Zealand: RCM mark, Australia/ NZ Emissions Compliant 309 Refrigeration Products Catalog

Articles in this issue

Archives of this issue

view archives of Wolseley - PENN Controls Products Catalog