Table 87: Sensors for the TC controller Product code Description EVTPN615F200-1C 10K ohm NTC sensor. IP67 protection level, overmolded thermoplastic material, 1.5 m (4.9 ft) cable length. Single pack, quantity of 1. EVTPN615F200-1D 10K ohm NTC sensor. IP67 protection level, overmolded thermoplastic material, 1.5 m (4.9 ft) cable length. Bulk pack, quantity of 100. EVTPN630F200-1C 10K ohm NTC sensor. IP67 protection level, overmolded thermoplastic material, 3.0 m (9.8 ft) cable length. Single pack, quantity of 1. EVTPN630F200-1D 10K ohm NTC sensor. IP67 protection level, overmolded thermoplastic material, 3.0 m (9.8 ft) cable length. Bulk pack, quantity of 100. EVTPNW15F200-1C 10K ohm NTC sensor. IP68 water resistant protection level, overmolded thermoplastic material, 1.5 m (4.9 ft) cable length. Single pack, quantity of 1. EVTPNW15F200-1D 10K ohm NTC sensor. IP68 water resistant protection level, overmolded thermoplastic material, 1.5 m (4.9 ft) cable length. Bulk pack, quantity of 100. EVTPNW30F200-1C 10K ohm NTC sensor. IP68 water resistant protection level, overmolded thermoplastic material, 3.0 m (9.8 ft) cable length. Single pack, quantity of 1. EVTPNW30F200-1D 10K ohm NTC sensor. IP68 water resistant protection level, overmolded thermoplastic material, 3.0 m (9.8 ft) cable length. Bulk pack, quantity of 100. Electrical ratings The following tables show the electrical ratings for single-pole, single-throw (SPST) and single- pole, double-throw (SPDT) control relays in the TC controller. Table 88: K1 compressor relay ratings cULus (UL 60730) CE (EN 60730) Applied voltage at 60 Hz 120 VAC 240 VAC 240 VAC TC3Bxx 12 A 12 A 10 A TC3Xxx 10 A 10 A 10 A Resistive amperes TC32xx 12 A 12 A 12 A Inductive amperes — — 2 A Full load amperes 10 A 10 A — Locked rotor amperes 60 A 60 A — Table 89: K2 defrost, evaporator fan or configurable relay ratings cULus (UL 60730) CE (EN 60730) Applied voltage at 60 Hz 120 VAC 240 VAC 240 VAC Resistive amperes 8 A 8 A 5 A Inductive amperes — — 2 A Full load amperes 4.4 A 2.9 A — Locked rotor amperes 26.4 A 17.4 A — Table 90: K3 evaporator fan relay ratings cULus (UL 60730) CE (EN 60730) Applied voltage at 60 Hz 120 VAC 240 VAC 240 VAC Resistive amperes 5 A 5 A 5 A Inductive amperes — — 1 A Full load amperes 1.5 A 1.5 A — Locked rotor amperes 9 A 9 A — Table 91: K4 cabinet light or configurable relay ratings cULus (UL 60730) CE (EN 60730) Applied voltage at 60 Hz 120 VAC 240 VAC 240 VAC Resistive amperes 5 A 5 A 5 A Inductive amperes — — 1 A Full load amperes 1.5 A 1.5 A — Locked rotor amperes 9 A 9 A — 82 Refrigeration Products Catalog

Articles in this issue

Archives of this issue

view archives of Wolseley - PENN Controls Products Catalog